Portable & Fixed Clamp-On Ultrasonic Flowmeters
Non-invasive ultrasonic flow measurement helps industrial plants measure suitable water and process liquids without interrupting a line. A portable meter can be useful for pump surveys, temporary verification, troubleshooting and metering feasibility; permanent clamp-on installations support process monitoring where cutting or welding pipework is not practical.
Send Technical RFQEmail Drawing / Datasheet
When clamp-on is a good solution
Portable survey: temporary measurement of water lines, pumps, cooling networks, chilled water, process transfers and comparative readings near existing meters. Fixed clamp-on: monitoring on process lines requiring non-invasive sensor mounting. Confirm the process liquid is compatible with the ultrasonic method: entrained gas, pipe lining, unsuitable pipe material, very low flow and limited straight length can degrade results.
Transit-time meters generally suit liquids that transmit a stable acoustic signal. Doppler-type meters require appropriate suspended reflectors; these are distinct measuring principles and cannot be exchanged solely on the basis of pipe size.
Representative models and accessories
| Reference | Purpose | Important technical check |
|---|---|---|
| KROHNE OPTISONIC 6300 P | Portable battery-powered transit-time clamp-on liquid meter | OEM describes portability, data logging and pipe sizes up to DN4000 depending sensors/variant |
| KROHNE OPTISONIC 6300 | Permanent clamp-on ultrasonic liquid measurement | Sensor rails, converter, probe temperature rating and mounting configuration |
| UFC 300 P / compatible transducers | Portable converter and appropriate transducer rail packages | Specify exact converter revision and sensor/rail kit; complete set may include cables, coupling, mounting straps and case |
| Other approved OEM packages | Single/dual-path transit-time ultrasonic | Pipe/material/calibration/outputs determine suitability |
Sizing: DN15 to DN4000 is not one sensor set
Portable systems typically use several transducer ranges, frequencies or mounts for smaller and larger diameter lines. For example, the OPTISONIC 6300 P family supports DN15–4000 in the OEM product description, but the supplied transducers and rail accessories must match the actual diameter range. A request for DN200–DN600 needs different physical components from many DN25–DN150 cases. Do not buy “a portable ultrasonic flowmeter” without confirming the complete clamp-on transducer/fixture set.
Prepare pipe and flow information
- External diameter, wall thickness, schedule, pipe material, coating/liner and accessible mounting length.
- Fluid type, process temperature, expected bubbles/solids, sound velocity or information for automatic configuration.
- Minimum/normal/max volumetric flow and number of meter installations or measurement sites.
- Required features: rechargeable battery, logger, thermal energy, 4–20 mA/pulse output, Bluetooth/software and calibration documentation.
- Transducer rails, straps, mounting grease/couplant, cable lengths, case and safe-area/access restrictions.
Measurement reliability
Correctly entering the internal bore and wall thickness is essential to velocity-to-volume calculations. Clamp-on measurement can be excellent for suitable conditions, but no reading should be advertised as custody-transfer approved unless the selected OEM version, installation and regulatory approval explicitly establish it. For legally billed transfer, verify a fit-for-purpose inline meter or approved metering arrangement.
What to send to AMAC for a quotation
- Pipe OD, ID or wall and liner, schedule and material
- Fluid type, temp and air/solids content
- DN ranges across the intended survey pipes
- Portable/fixed, logging, power, outputs and calibration deliverables
- Full accessories/transducer mounting kit plus quantity and delivery city
Technical quotation and field review
AMAC can review a complete instrument or project RFQ, including OEM replacement identification, site survey, installation, wiring, calibration or commissioning scope where applicable. Submit the instrument index, BOQ, data sheet and required end-user approvals.
sales@amac-group.com · +966 53 217 2711 · online contact form
OEM products are mentioned for engineering identification only; references are not proof of AMAC authorization, inventory, compliance or pricing. Final model, approvals, availability and delivery are established by supplier confirmation and the accepted quotation.
Further reading and related products
Water metering · Mag meter alternative · Technology comparison · Onsite instrumentation services