A M A C G R O U P

Loading

Process Instrumentation & Transmitters Saudi Arabia | AMAC

Industrial Instrumentation | AMAC Group Saudi Arabia

Industrial Process Instruments: Flow, Level, Pressure, Temperature & Analyzers

A practical industrial instrumentation catalogue for Saudi procurement and EPC buyers: select a measurement technology by medium and application, then submit an instrument index, BOQ or exact model code for a technically defensible AMAC quotation. Priority families include water and diesel flowmeters, process transmitters, analyzers and complete E&I packages.

Request Technical RFQEmail BOQ / Datasheets

Measurement families and detailed buying guides

CategoryTechnology or useSelection guide
FlowmetersElectromagnetic, positive displacement, turbine, ultrasonic, Coriolis, vortex, thermal mass, DP and moreAll flowmeter types
Water and wastewaterMagmeter and non-intrusive clamp-on, large DN municipal pipesElectromagnetic water meters
Diesel and refined fuelsLiquid Controls M-Series rotary PD, liquid turbine and CoriolisLC PD diesel · Diesel turbine
Gas and steam flowThermal mass, vortex steam, gas ultrasonic and turbineGas metering · Steam vortex
Tank and process levelNoncontact radar, guided-wave radar, hydrostatic/DP and level switchRadar/GWR level
Pressure and DPGauge, absolute, DP, impulse lines and diaphragm sealsPressure/DP transmitters
TemperaturePt100/Pt1000 RTDs, thermocouples, thermowells and transmittersTemperature assemblies
Online analysisO2, CO, H2S, combustion, pH, turbidity, conductivity, chlorine and DOGas/water analyzers
Metering controlFlow computers, compensated volume, batch totalizers, instrument packagesFlow computers

Water, desalination and wastewater plants

Conductive municipal/process water often fits full-bore magmeters; portable clamp-on ultrasonic can support temporary verification. Radar/pressure instruments monitor tank levels, while online conductivity, chlorine, pH and turbidity instruments support water quality. Provide fluid details, DN size, liners, grounding, instrument power and telemetry requirements.

Diesel fuel, bulk loading and vehicle monitoring

For diesel transfer, evaluate LC M-series positive displacement, liquid turbine and Coriolis for different viscosity, batch, accuracy and pressure-drop requirements. Fuel level telemetry and GPS monitoring is a separate system scope. A water electromagnetic flowmeter is not a reliable replacement for a diesel hydrocarbon line because diesel is non-conductive.

Oil, gas, EPC and E&I packages

Project procurement may require gas ultrasonic, thermal mass, vortex steam, pressure and DP transmitters, analyzer shelters, temperature probes, flow computers, instrument panels, calibration, loop-check and FAT/SAT. Reference models include Liquid Controls M-Series, KROHNE OPTISONIC/OPTISWIRL/OPTIMASS, Endress+Hauser Promag/Deltabar, Siemens SITRANS, Emerson Rosemount, Kurz 454FTB/K-BAR. Part numbers identify a required OEM family and do not establish available inventory or authorization.

A complete instrument index shortens quotation time

  • One row per tag: make/model or process medium, measurement principle and engineering purpose.
  • Pipe sizes, ranges, maximum and normal flow, pressure and temperature, fluid properties and materials.
  • For pressure, level and temperature: span, wetted parts, thermowells, process connections and transmitter mounting.
  • For analyzers: component species/concentration, sample conditioning, calibration gases and site standards.
  • Power, 4–20mA/HART/Modbus/fieldbus, area classification, IP rating and control system.
  • BOQ, approved manufacturer list, required certificates, calibration/FAT/SAT and delivery schedule.

Project handover and field integration

AMAC supports supply-led and project technical enquiries; details must be priced against actual approved scope rather than inferred from a product listing. Separate supply, installation, wiring/termination, loop tests, calibration, commissioning and ongoing service requirements for comparison. View project work and industrial services.

What to provide for quotation

  • Buyer and project site, RFQ closing date and vendor/technical evaluation format
  • BOQ/instrument list with quantity, exact tag number or OEM model
  • Fluid, line size, measured range, design P/T, enclosure and wetted materials
  • Required calibrated uncertainty, certificates, Ex ratings and project specs
  • Digital protocol, electrical scope, supports, test and installation requirements
  • Delivery city and scope breakdown by supply/service

Speak to AMAC Sales

Provide exact make/model and serial number for a replacement or instrument index, P&ID, datasheets, BOQ, project specification and approved-vendor requirements for new installations and E&I packages.

sales@amac-group.com · +966 53 217 2711 · RFQ contact form

OEM families are technical identification references, not claims of AMAC manufacturer authorization, stocked parts or guaranteed certification. Confirm model/approvals and delivery before procurement.

Related measurement and instrumentation

Flowmeter selection · E&I project RFQs · Industrial services · Tanker telemetry

Water metering: branded model reference guides

Two further technical identification guides cover exact ABB AquaMaster4 FEW432 and Siemens SITRANS MAG 8000 water-network models. AMAC evaluates approved OEM requirements without implying manufacturer agency or stock.

AquaMaster FEW432   ·   Siemens MAG 8000

Send model code and datasheet to AMAC Sales.