A M A C G R O U P

Loading

Temperature Transmitters RTDs & Thermocouples Saudi Arabia | AMAC

AMAC Group | Saudi Industrial Instrumentation

Temperature Transmitters, RTDs, Thermocouples & Thermowells

Industrial temperature procurement combines the sensor, transmitter, thermowell, process connection and control-system configuration. AMAC reviews head-mount, DIN-rail and field transmitters together with Pt100 RTDs, thermocouples, dual-element sensors and temperature assemblies for Saudi petrochemical, water, power and general manufacturing plants.

Request RFQEmail Instrument Datasheets

RTD, thermocouple or transmitter: specify each separately

DeviceApplication strengthKey limitation / input
Pt100 / Pt1000 RTDGood repeatability and accuracy in typical industrial temperature ranges2-, 3- or 4-wire wiring and lead resistance; sensor construction
Thermocouple (K, J, T, N, S, R, B)Broad high-temperature/high-response applications depending on typeCorrect thermocouple grade, extension cable, polarity and cold-junction compensation
Head-mount transmitterIntegrated thermowell/sensor assembly with HART / 4–20 mA outputMounting head, terminal clearance, ingress and hazardous area
DIN-rail transmitterPanel marshalling cabinets and remote sensorsDIN-rail space, input wiring, isolation and cabinet temperature
Thermowell / protection tubeProtects sensor from process and allows selected replacementsInsertion length, bore, alloy, pressure/temp, flange/thread and vibration engineering

Manufacturer reference for technical RFQs

Rosemount 644: established temperature transmitter family supporting RTD/thermocouple inputs in different head/rail variants and HART/fieldbus configurations. For equivalent models, confirm output, input sensor type, diagnostics, hazardous approval and whether a sensor assembly is required. A transmitter-only quote is not an RTD probe or a thermowell package.

Critical assembly details

  • Element: Pt100 IEC 60751 class / thermocouple type and tolerance; single or duplex sensing elements.
  • Probe diameter and hot insertion length U, sheath/thermowell material 316SS/Inconel/approved alloy and process connection.
  • Operating and maximum temperature, pressure and corrosion/erosion risk.
  • Response time, mechanical vibration, orientation and thermowell wake-frequency calculation if required.
  • 3-wire vs 4-wire RTD; thermocouple compensation/extension cable material; grounding and shielding.
  • 4–20 mA/HART/fieldbus output, power, fault upscale/downscale, display and DCS range.
  • End-user calibration, factory inspection and traceability documentation required by project.

Temperature assembly and installation scope

For a complete installation, request instrument assembly drawings, thermowell calculations if specified, insertion nozzle, transmitter head, cable gland, multicore wiring, cable termination, loop check and field temperature verification. A replacement head or sensor must match the existing thermowell bore and connection; never force an incompatible diameter or assume immersion depth is interchangeable.

Application examples

Boiler and steam: high-temperature thermocouple/RTD and suitable protection assembly. Process tanks: Pt100 with local head transmitter and proper insertion. Control panels: rail-mount conversion of RTD/thermocouple into 4–20 mA/fieldbus. Heat exchangers: supply/return temperature pairs with sensor matching and documented accuracy.

Information required for a reliable technical quotation

  • RTD Pt100/Pt1000 or thermocouple type, number of sensing elements and class
  • Temperature min/normal/max, pressure, corrosion medium and insertion length
  • Process thread/flange, thermowell size/design, sheath material, sensor diameter
  • Head/rail/field transmitter, outputs, hazardous-area approval and calibration
  • Required probe/transmitter/thermowell quantity, tag and model code
  • Manufacturer replacement code and site drawing or instrument datasheet

Contact AMAC Saudi Arabia

For an instrument replacement, send the manufacturer name, complete original model and serial number, existing range, process connections and datasheet. For EPC and E&I packages, attach the BOQ, instrument index, P&ID, technical datasheets and approved vendor requirements.

sales@amac-group.com · +966 53 217 2711 · Contact form

Brand/model examples are identification references only, not claims of OEM agency, stock, fixed price, performance guarantee or Saudi end-user approval. Final acceptance depends on selected variant, application and current OEM documents.